Construction issues to be noted in lightning protection and grounding engineering

Time:2022-08-13

At present, power production companies and some factories are basically inseparable from lightning protection and grounding engineering. During construction, design and operation personnel need to develop corresponding engineering plans based on their company's geographical location and do a good job in overall deployment. However, do you know what issues need to be paid attention to when carrying out lightning protection and grounding engineering construction? What problems should be avoided during construction to ensure the smooth progress of lightning protection and grounding projects? Below, the manufacturer of flexible graphite grounding strips will provide a detailed introduction to three points:


1. Pay attention to the welding method

Flexible graphite grounding strip manufacturers remind everyone that during the construction process of lightning protection grounding engineering, construction personnel must pay attention to some construction details, such as the welding of jumper steel bars, the welding method of jumper steel bars between grounding steel bars, etc., which require everyone to communicate and prepare in advance. Many workers may not pay attention to the overlap length of welding, which will lead to the failure of the task. Therefore, everyone should pay attention to the welding method and not take it lightly;


2. Pay attention to offline cross soldering connections

When carrying out lightning protection grounding engineering, the steel bars of the lightning protection down conductors inside the columns should be cross welded and connected to each other. To avoid lightning accidents caused by unreliable welding of steel bars and the inability of lightning currents to conduct underground, cross welding connections must be made between multiple down conductors. After the construction is completed, the lower steel bars should be marked to facilitate identification for the next construction;


3. Pay attention to reserving flat steel

When welding the basic lightning protection grounding device, flat steel should be reserved. The manufacturer of flexible graphite grounding strip reminds everyone that when the lightning protection test resistance value does not meet the design requirements, it can be convenient to make artificial grounding electrodes to avoid damage to the main body of the building. Generally, professional lightning protection grounding engineering companies in China will pay attention to these details during construction;

The above points are the construction issues that should be paid attention to in lightning protection and grounding engineering introduced by flexible graphite grounding strip manufacturers. We hope that every construction worker can raise their vigilance in this regard. When looking for a grounding company, it is necessary to first examine the company's strength, and then comprehensively compare and select a reliable lightning protection and grounding engineering company. This can ensure that there will be no defects in the later construction, thereby bringing safety assurance to everyone.